Section 3. FUNCTION 49
3.3 Selecting SINK/SOURCE operating mode (JP1)
E32A can be programmed so that the J1 connector outputs and inputs operate in the SINK or SOURCE
mode. To program the operating modes install the jumpers JP1 on the circuit board as indicated in the
Figure 3-4).
Figure 3-4. Selecting SINK/SOURCE operating mode.
(*) Note: Default condition
A
Sink
Mode
B (*)
Source
Mode