3.4 Manual Mida Tool EYE management with Electrical E32A
The Electrical E32A SSR can be forced to emulate the Manual E32A SSR. Use the following connection
diagram, depending on the sink/source mode selected for the E32A SSR.
SOURCE programmed E32A SSR SINK programmed E32A SSR
Connect pins 18 (Arc) and 19 (Mrc) to the +24Vdc
supply. Connect as shown in the figure.
Connect pins 18 (Arc) and 19 (Mrc) to the GND 0 V
supply. Connect as shown in the figure.
Figure 3-5. Manual application management with E32A